header image scientific

Bibliography

Our instruments are used by top reserchers world wide, including recent nobel prize winners, such as W.E. Moerner and S.W. Hell. Our bibliography is a collection of papers that mention explicitly PicoQuant or at least one of our product's name. Searching or browsing through the bibliography allows to find out which laboratories use PicoQuant devices and what type of applications have been reported so far.

The bibliography contains articles mentioning explicitly PicoQuant or at least one of our product's name (e.g. MicroTime). Most of the references can be found easily by full-text searches on the internet. However, some papers cite us only indirectly, sometimes not at all. Such publications are included only if the use of a PicoQuant product is known, for example, based on communication with the author(s). There are certainly many more articles reporting results obtained using PicoQuant devices. Unfortunately, such papers are often hidden for us. Please help completing this list.
Do you miss your publication? If yes, we will be happy to include it in our bibliography. Please send an e-mail to info@picoquant.com containing the appropriate citation. Thank you very much in advance for your kind co-operation.

more..


Searching for

8789 results found.


Time-resolved fluorescence measurements of cyanine dyes in biomimetic systems

Luschtinetz F., Kumke M. U., Dosche C.
Proceedings of SPIE, Vol.7576, 757619 (2010)

Reference to: MicroTime 200, SymPhoTime, HydraHarp 400
Related to: FCS, Anisotropy, Time-resolved Fluorescence


Time-resolved near-infrared technique for bedside monitoring of absolute cerebral blood flow

Diop M., Tichauer K. M., Elliott J. T., Migueis M., Lee T.-Y., Lawrence K. S.
Proceedings of SPIE, Vol.7555, 75550Z (2010)

Reference to: Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)


Scanning FCS for the characterization of protein dynamics in live cells

Petrášek Z., Ries J., Schwille P.
Methods in Enzymology, Vol.472, p.317-343 (2010)

Reference to: MicroTime 200, LSM Upgrade Kit
Related to: FCS


Near infrared photodetector based on polymer and indium nitride nanorod organic/inorganic hybrids

Lai W., Li S., Lin Ch., Kuo Ch., Chen Ch., Chen K., Chen L.
Scripta Materialia, Vol.63, p.653-656 (2010)

Reference to: Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)


A phosphorescent poly(dendrimer) with increased viscosity for solution-processed OLED devices

Levell J. W., Gunning J. P., Burn P. L., Robertson J., Samuel I. D. W.
Organic Electronics, Vol.11, p.1561-1568 (2010)

Reference to: Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)


Functional imaging using diffuse optical spectroscopy of neoadjuvant chemotherapy response in women with locally advanced breast cancer

Soliman H., Gunasekara A., Rycroft M., Zubovits J., Dent R., Spayne J., Yaffe M. Y., Czarnota G. J.
Clinical Cancer Research, Vol.16, p.2605-2614 (2010)

Reference to: Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)
Related to: Diffuse optical tomography


Visualization of the Orai1 homodimer and the functional coupling of Orai1-STIM1 by live-cell fluorescence lifetime imaging

Huang P., Chiu T., Wang L., Teng H., Kao F., Yang D.
Microscopy and Microanalysis, Vol.16, p.313-326 (2010)

Reference to: TimeHarp 100/200, SymPhoTime, PMA Series, LSM Upgrade Kit, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)
Related to: FLIM, FRET, Time-resolved Fluorescence


Kinetics of a single cross-bridge in familial hypertrophic cardiomyopathy heart muscle measured by reverse Kretschmann fluorescence

Mettikolla P., Calander N., Luchowski R., Gryczynski I., Gryczynski Z., Borejdo J.
Journal of Biomedical Optics, Vol.15, 017011 (2010)

Reference to: PicoHarp 300, FluoTime 200, FluoFit, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)
Related to: FCS


Donor-acceptor nonradiative energy transfer mediated by surface plasmons on ultrathin metallic films

Jankowski D., Bojarski P., Kwiek P., Rangełowa-Jankowska S.
Chemical Physics, Vol.373, p.238-242 (2010)

Reference to: TimeHarp 100/200, FluoFit


Single-molecule spectroscopy of protein folding in a chaperonin cage

Hofmann H., Hillger F., Pfeil S. H., Hoffmann A., Streich D., Haenni D., Nettels D., Lipman E. A., Schuler B.
Proceedings of the National Academy of Sciences of USA, Vol.107, p.11793-11798 (2010)

Reference to: MicroTime 200, SymPhoTime, HydraHarp 400
Related to: FRET


Spectrometer and method of operating a spectrometer

Graves P.
Patent, WO2010007386 (2010)

Reference to: PicoHarp 300, HydraHarp 400, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)


Blocked electron transfer and suppressed blinking of single CdSe/ZnS quantum dots in agarose gel

Ko H. C., Yuan C. T., Lin S. H., Tang J.
Journal of the Chinese Chemical Society, Vol.57, p.522-527 (2010)

Reference to: PicoHarp 300, MicroTime 200, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), SymPhoTime
Related to: Single Molecule Detection


Biomimetic bilayer membranes made from polymers and lipids

Dorn J.
PhD. Thesis, Johannes Gutenberg Universität Mainz, Germany (2010)

Reference to: Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), PicoHarp 300, SPADs
Related to: Single Molecule Detection


Functional modules in the Arabidopsis core cell cycle binary protein-protein interaction network

Boruc J., Van den Daele H., Hollunder J., Rombauts S., Mylle E., Hilson P., Inzé D., De Veylder L., Russinova E.
Plant Cell, Vol.22, p.1264-1280 (2010)

Reference to: PicoHarp 300, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), SymPhoTime, LSM Upgrade Kit, SPADs


Novel method for quantitative and structural determination of molecular complexes by photon antibunching

Ta H.
PhD. Thesis, Ruprecht-Karls-Universität, Heidelberg, Germany (2010)

Reference to: HydraHarp 400, TimeHarp 100/200, FluoTime 100, FluoFit, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), PLS Series
Related to: Antibunching


CdTe quantum dot/dye hybrid system as photosensitizer for photodynamic therapy

Rakovich A., Savateeva D., Rakovich T., Donegan J. F., Rakovich Y. P., Kelly V., Lesnyak V., Eychmüller A.
Nanoscale Research Letters, Vol.05, 753 (2010)

Reference to: PicoHarp 300, MicroTime 200, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), SymPhoTime
Related to: FLIM, FCS, Time-resolved Fluorescence


A miniaturized XeCl dielectric barrier discharge as a source of short lived, fast decaying UV radiation

Bussiahn R., Pipa A. V., Kindel E.
Contributions to Plasma Physics, Vol.50, p.182-192 (2010)

Reference to: NanoHarp 250


Fatty acids from very low-density lipoprotein lipolysis products induce lipid droplet accumulation in human monocytes

den Hartigh L. J., Connolly-Rohrbach J. E., Fore S., Huser T. R., Rutledge J. C.
The Journal of Immunology, Vol.184, p.3927-3936 (2010)

Reference to: SymPhoTime, TimeHarp 100/200


Enhanced fluorescence of curcumin on plasmonic platforms

Mukerjee A., Luchowski R., Ranjan A. P., Raut S., Vishwanatha J. K., Gryczynski Z., Gryczynski I.
Current Pharmaceutical Biotechnology, Vol.11, p.223-228 (2010)

Reference to: PicoHarp 300, MicroTime 200, FluoTime 200, FluoFit, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), SymPhoTime
Related to: FLIM, Time-resolved Fluorescence


Advantages of fluorescence over diffuse reflectance measurements tested in phantom experiments with dynamic inflow of ICG

Milej D., Kacprzak M., Żołek N., Sawosz P., Gerega A., Maniewski R., Liebert A.
Opto-Electronics Review, Vol.18, p.208-213 (2010)

Reference to: Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)


Synthesis and characterization of a fluorescent water-soluble Paclitaxel prodrug

Sohn J.-S., Choi E.-S., Jo B.-W., Hess M., Han S.-H.
Journal of Nanoscience and Nanotechnology, Vol.10, p.3478-3483 (2010)

Reference to: FluoFit
Related to: Time-resolved Fluorescence


A film luminescent nanosensor based on a quantum dot-organic molecule complex

Orlova A. O., Maslov V. G., Toporova Y. A., Ushakova E. V., Fedorov A. V., Artem’ev M. V., Baranov A. V.
Nanotechnologies in Russia, Vol.5, p.49-57 (2010)

Reference to: MicroTime 100, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), TimeHarp 100/200, SymPhoTime


Non-radiative resonance energy transfer in bi-polymer nanoparticles of fluorescent conjugated polymers

Ozel I. O., Ozel T., Demir H. V., Tuncel D.
Optics Express, Vol.18, p.00670-00684 (2010)

Reference to: PicoHarp 300, FluoTime 200, FluoFit, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), PMA Series
Related to: FRET, Time-resolved Fluorescence


A fluorescence correlation spectroscopy study of the diffusion of an organic dye in the gel phase and fluid phase of a single lipid vesicle

Ghosh S., Adhikari A., Mojumdar S. S., Bhattacharyya K.
Journal of Physical Chemistry B, Vol.114, p.05736-05741 (2010)

Reference to: PicoHarp 300, MicroTime 200, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series), SymPhoTime
Related to: FCS


Dendrimer internalization and intracellular trafficking in living cells

Albertazzi L., Serresi M., Albanese A., Beltram F.
Molecular Pharmaceutics, Vol.07, p.0680-0688 (2010)

Reference to: MicroTime 200, Pulsed Diode Lasers (PDL Series, LDH-Series, LDH-FA Series)
Related to: FCS